S390H/L DIGITAL HD OPHTHALMIC SLIT LAMPS - MOTORIZED FOCUSING
























































































email
Eye4Vision Int'l.
S390H/L Digital Slit lamps
®
Home
1
1

S390H/L Digital Diagnostic Slit Lamps - Motorized Focusing - 4x Zoom - HD Video

Specifications

DIGITAL

Imaging System

Type
Magnification change
Eyepieces
Angle between eyepieces
Total magnification Ratio
Pupillary adjustment
Diopter adjustment
Field of view
Galilean Type slit lamp
Five Position revolving Drum
12.5X
13º
6X, 10X, 16X, 25X, 40X
52mm - 78mm
+6.0D ~ -6.0D
40X ( 5.5mm ), 25X ( 8.5mm ), 16X ( 13.5mm ),
10X ( 22mm ), 6X ( 34.7mm )
Slit llumination
Slit width
Slit length
Aperture diameters
Slit angle
Slit inclination
Filters
Illumination S390H
Illumination S390L

Power
Input voltage
Input frequency
Power Consumption

Base
Longitudinal movement
Lateral movement
Vertical movement
Fine base movement

Chin-Rest
Vertical movement
Fixation
Backlite illumination module

Power
Input voltage
Input frequency
Power Consumption

Output Voltage
Halogen bulb
Led
Fixation Led
Backlit illumination Led

Dimensions & Weight
Dimensions br>Net weight
Gross weight
Continuously variable from 0 to 14mm ( slit becomes a circle at 14mm )
Continuously variable from
1.0mm to 14mm
14mm, 10mm, 5mm, 3mm, 2mm, 1mm, 0.2mm, 1 to 14mm continuous  
0°-180°( continuously adjustable, vertical and horizontal )
4 step 5°, 10°, 15°, 20°
Thermal safety, Red-free, Cobalt Blue, UV
Halogen bulb 6V20W - ≥ 60,000 Lux
LED Module 3V/3W - ≥ 100,000 Lux


AC-110/220V
50Hz/60Hz
10VA ( max )


90mm
100mm
30mm
15mm


80mm
LED
LED


AC 220V / 110V
50Hz/60Hz
Type S390H - 30W (max) Halogen bulb
Type S390L  - 20W (max) LED module

S390H - 6V ( continuously adjustable )
S390L - 3V ( continuously adjustable )
3V
3V


770mm x 470mm x 570mm
25Kg
27Kg
-
-
-
-
-
-
-
-
S390H/L Specifications (  H = Halogen Bulb,  L = Led Light illumination )
Image sensor
Still image resolution
Photo format
Video resolution

Shooting Mode
Manual Mode
Continuous Mode
Viewfinder
Embedded intelligent OS
Transmission interface
Power Supply
1/2.5 inch high-speed, high-definition sensor
2592 x 1936
jpeg
1920 x1080 ( Full HD ) 25fps   
1396 x 960 ( HD ) 30fps   
Manual & Continuous Mode
Focusing and shooting with mouse wheel
Auto focus
Computer screen
Auto-exposure, Auto-gain and Auto-white balance
RJ45, compatible with 100/1000M ethernet, multicast available
Powered by network according IEEE802.3af 48VDC

Specifications Slit Lamp Imaging System

PC/ Laptop & Software Configuration
1
OS Requirements
CPU
Memory
Screen resolution
Graphic card
Printer
Software
Operating System
Graphic card setting
Network IP configuration
Firewall setting
2.0Ghz or above
1024Mb or above
1280 * 1024, minimum requirement 17" monitor
Independent ATI or NVIDIA grahic card
Color printer, A4 recommended
MediView Software ( included )
WindowsXP or Win7 ( Windows Vista is not supported )
Color quality: 24 bytes or above
192.168.1.XX ( 1-255, except 9 )
Turn off firewall before running the Mediview software
s390h - s390l slit lamps
-
-
-
-
-
-
-
-


-
-
-


-
-
-
-


-
-
-


-
-
-
-

-
-
-
-


-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-

-
-
-
-
-
TOP
Restore Sight
digital slit lamp system with hd video
The Image Censor and MediaView Imaging and Management System producing clear
and sharp Still Images and HD Video recording with a resolution up to 5 Megapixels.
ce - fda







pc - laptop - printer
World's First Motorized Focusing System of the S390H/ S390L digital slit lamps generates
sharp and clear digital images, by slightly moving the finger on the Mouse wheel.
The intelligent camera sensor system with 4x Zoom capacity perfectly integrates
Auto-exposure, Auto-gain and Auto-white balance.
●   Features
It provides an option to view the patient's eye either through the slit lamp microscope eyepieces,
or directly from the computer or laptop screen.