background
APS-T90 split unit
Static & Dynamic Perimetry Modes are included in the APS-T00 / APS-T90 Series Automatic Projection Perimeters,
for Accurate Visual Field Analysis. Blue / Yellow ( SWAP ) Contrast Perimetry, Stimulating Red, Red / White and
White / White Color perimetry for fast detection of
current and earlier visual defects of patient's eyes.
Eye4Vision Int'l.
®

PERIMETRY - COMPUTERIZED PROJECTION PERIMETERS APS-T00 / APS-T90

email
Home
ce-fda
computerized perimeter
Computerized Projection Perimetry
PERIMETRY
Projection Perimeters


Stimulating way

Projection surface

Detection Method


Detection Scope

Brightness Level

Testing Distance

Visual Target Color

Visual Target Brightness

Background Light


Vision Target
Interval Time Program
Holding Time Program

Pupil Size Measurement

Head Movement Controls

Brightness Measurement

Visual Target Size
Class I
Class II
Class III
Class IV
Class V

Detection Strategy


Threshold Policy

Static Perimetry
Threshold Test Mode

Screening, Special Test Mode




Dynamic Perimetry
Dynamic Program




Stimulation Parameters

Fixation Monitoring


Eye Positioning Monitoring

Eye Tracking


Analysis Software



Report Figure



Chin Rest Stroke

Power

Weight ( Net / Gross )


Packing
Dimensions

APS-T00 / APS-T90 Automatic Visual Field Analyzers - Static / Dynamic / Color Perimetry

APS-T90
● Color Perimetry, a more sensitive detection of early Visual Field defects
● Intelligent Testing Strategies: 3 minutes to complete a Full Diagnostic Threshold
● Accurate, Automated Static or Dynamic Perimetry Test Results
● Comprehensive and versatile single analysis and reporting reliability
● Perimeter Index: Average Deviation, Graphics Deviation, GHT Half Glaucoma Vision Analysis, Visual Field Index ( VFI )
● Dedicated projection perimeter software system, Powerful Data file management
● Standard Dicom 3.0 interface to access hospital HIS, PACS or Medical Network
1
APS-T00 / APS-T90 - Specifications
Specifications
:
:

:

:

:
:

:

:

:

:

:

:
:

:
:
:

:

:

:

:
-
-
-
-
-

:


:


:

:





:




:

:


:

:


:



:



:

:

:
:

:
:
:
1
APS-T00, Internal Computer, Touch screen
APS-T90, Split Unit, External Computer

Optical Projection

Aspheric Projection Arc

Static Perimetry
Dynamic Perimetry

0 - 90°

0 - 51dB

300mm

Red, Blue, White

0asb - 10,000asb

White 31.5asb
Yellow 315asb

Patient Adaptive, Standard, Slow, Custom
Adjustable from 0.1s - 2.0s
Adjustable from 0.1s - 2.0s

Auto

AEC Eye Position monitoring and Automatic Correction system

Brightness Auto Measurement and correction

Goldmann Standard
Angle 0.11°, Stimulus as standard size ( Bowl 30cm )
Angle 0.22°, Stimulus as standard size ( Bowl 30cm )
Angle 0.43°, Stimulus as standard size ( Bowl 30cm )
Angle 0.86°, Stimulus as standard size ( Bowl 30cm )
Angle 1.72°, Stimulus as standard size ( Bowl 30cm )

Full Threshold, Fast Threshold, Custom, Two notations, Three notations,
Quantify detects, Intelligent Dynamic, Fast Intelligent Dynamic

Age Related, Threshold Related, Single Strength


Center 10-2, Center 24-2, Center 30-2, Center 60-4, Nasal step, Macula

Center 40, Center 64, Center 76, Center 80, Center Armaly, Peripheral 60,
Nasal Step, Full Field, Full Field 81,Full Field 120,
Full Field 35, Full Field 246, Upper 36, Upper 64,
Esterman Monocular, Esterman Binocular


Manual Procedures, Standard Procedures
( Standard 45, Standard 30, High resolution 15,
Static Point map, Dark Spot map, Blind Spot map,
Custom Scan, Custom Dynamic Program )

Adjustable, Speed 1-9/s, Visual Target size, Color, Intensity, Test ranges etc.

Dynamic Real-time Video monitoring, Physiological Blind Spot monitoring
Eye Tracking Curve

CCD Camera, instantly monitoring the eyes

Auto Alarm signal when Eye movements or Eye blinking appear
Auto Alarm Mode On: 'Start eye movement detection'

Reliability analysis, Single Vision analysis, Triple Report analysis,
Overview Vision analysis, GHT Glaucoma Semi Vision analysis,
GPA Glaucoma Developing analysis

Value map, Grayscale map, Overall Bias Decibel chart,
Overall Deviation Probability map, Chart Pattern Deviation decibels,
Pattern Deviation Probability plot, Starting Figure

50mm

AC 220V 60Hz / AC 110V 50Hz.

APS-T00, 40.0Kg / 72.0Kg
APS-T90, 35.0Kg / 70.0Kg ( Without PC ), 45.0Kg / 85Kg ( With PC )

Wooden Box, Outside Carton
APS-T00 / T90, 90.0 * 81.0 * 117cm
APS-T90 with PC, Extra Box: 68.0 * 52.0 * 47.5cm
Features
Features
1/4mm2 ( ±10% )
1mm2 ( ±10% )
4mm2 ( ±10% )
16mm2 ( ±10% )
64mm2 ( ±10% )
APS-T00


















































































































TOP
Computerized Perimetry