Introduction:
Intra-stormal implants or Intra corneal Rings, Segments or ICRs were designed and developed to be used as
a correction for reducing or eliminating myopia.
They are also used for the correction of keratoconus if properly implanted into the stroma of the cornea,
outside of the optic zone.
icr
Intra-stromal segments are now becoming a normal tool in the surgeon's arsenal against poor vision.
Unlike the original segments that necesitated the surgeon purchasing a multi-thousand dollar piece of
equipment and special instrumentation, products like KERATACx™ can be used by most surgeons without
expensive instrumentation.
Improvements in Pachymetry and corneal topography have increased the use of intra-stromal segments,
intra corneal rings or implants.
1
1
1
Products  Foldable intraocular lens  PMMA iols  Viscoelastics  Phacoemulsification system  Intra-stromal inlays  CTRs  Sutures  Instruments  Sterilizers  Economy  Links  Search

INTRA STROMAL INLAYS OR INTRA CORNEAL RINGS - INTRODUCTION

Eye4Vision Int'l.
®
email
ovd
ICR
CTR
pmma
products
phaco system
instruments
sterilizers
links
search
sutures
Home
economy
TOP
Introduction
1
back
About us  Cataract Surgery Packs  VISION2020  Cannula  Ophthalmic microscopes  Donate here  Cataract kit  Sitemap

foldables
made in usa

Introduction
Corneal Inlays

KERATACx™
intra corneal
rings

Vejarano™
Delaminator
System
foldable inlays
corneal inlays
The implant changes the surface shape of the cornea following implantation because they are implanted
approximately 75% of the way into the periphery of the cornea thru a small radial incision and tunnel
created in the stroma.
The tunnel or elongated pocket can be created by using an manual instrument or a laser following the wound
puncture, which must not be to deep so as to perforate the cornea. Once formed, the implant is carefully
inserted into the tunnel and the shape of the cornea is changed so as to create better vision for the patient.
The amount of correction depends upon the thickness of the implant and they are designed to be used in pairs.
They may be implanted in a clockwise or counter clockwise direction depending on the intra stromal tunnel and
surgical technique due to the hole at each end. This hole may be used for manipulation and removal.
The optical zone of KERATACx™ is 4.2-5.8mm, KERATACx Plus™ is 5.4-5.6mm,
KERATACx SP™ is 5.8-6.0mm and KERATACx V™ offers an optical zone of >6.0mm
Reducing or eliminating Myopia or correction of Keratoconus
The design of KERATACx allows for their extraction from either end and replacement if necessary. They are
transparent and each ring covers 160º degrees.
They are manufactured from the world’s finest PMMA and are currently available from  
100 microns to 350 microns in 25 micron increments.
Vejarano Delaminator System™
The World's First affordable corneal delaminating system for Keratoconus, designed to improve results and prevent
corneal perforations, and manufactured of the finest medical grade Titanium or Stainless steel.
Surgeons around the world report that patients experience no glare, halos, sparkles or star bursts, after implantation
of KERATACx™ branded ICRs with the
Vejarano Delaminator System™.
Intra stromal inlays
1
Correction
Replacement
Implantation
Delaminator System
Cost-effective
Intra corneal rings