During the past few years there have been tremendous developments in ophthalmic,
dental and surgical technology. It is not surprising that sterilizing technology has
finally caught with the needs of modern surgery.
STATIM S-CYCLE CASSETTE STERILIZERS
STATIM S-sycle, unique patented technology.
Positive Pressure Pulse Displacement actively removes air from
the chamber to create a “Positive Pressure Pulse Pre-vacuum”.
The STATIM sterilizers fully comply with:
♦ European Standard EN 13060  
♦ Australian / New Zealand AS/NZS 4815
♦ FDA for sale in the USA
CLASS 'S' cycle
Positive Pressure Pulse Vacuum      ( Active Air Removal )
For sterilizing specifically defined loads including hollow phaco handpieces,
wrapped and porous loads.
BIOLOGICALLY ACCURATE
100% biologically accurate every cycle.
Independent microbiological research shows that sterilization is achieved in half a cycle.
These research papers are available upon request
Water
The STATIM cassette autoclave uses clean “good quality distilled water every cycle and research
shows that there is no detectable endotoxins in the water reservoir of the STATIM.
Re-cycling dirty contaminated water is certainly no longer acceptable and the reservoir holds
sufficient water for 30 cycles
Sterility assurance   
The STATIM 'S' Cycle validates its own successful cycle as a computerized microprocessor abort
the cycle if either the parameters of temperature or time are not achieved.
Validation
Daily validation can be done in the wrapped cycle with a “Super Atmospheric Pressure” Helix.
♦ Tracking
Tracking is easy and accurate with “POINT OF CARE” sterilization between patients,
the validation printout can be attached to the patient card to prove sterility for every patient.
It is extremely user friendly as it works with the touch of a button on a Key Pad and a display
tells the operator exactly what to do.
2000S
The STATIM S-cycle cassette autoclave is a bespoke sterilizer in that it is
validated micro-biologically by independent research institutes and tested for
specific instruments. These include all major brands of handpieces.
STATIM2000 / 5000  S-Cycle Autoclaves - New Technology in medical sterilization
5000S
Products  Foldable intraocular lens  PMMA iols  Viscoelastics  Phacoemulsification system  Intra-stromal inlays  CTRs  Sutures   Instruments  Sterilizers  Economy  Links  Search
Eye4Vision Int'l.
®
email
ovd
CTR
pmma
products
phaco system
instruments
sterilizers
links
search
sutures
Home
economy
TOP
Autoclaves
foldables
ICR
Steam Sterilizers
About us  Cataract Surgery Packs  VISION2020  Cannulae  Microscopes  Projects 2008  Donate  Cataract kit  Sitemap

STERILIZERS
STATIM
900
2000
5000
2000S
5000S
7000
STATIM
Dri-Tec
Drying
Technology
STATIM
Specifications
Accessories
SciCan
AquaStat
water distiller


statim 900
statim 7000
statim 2000 and 5000
aquastat
dri-tec
STATIM2000S
STATIM5000S
CASSETTE AUTOCLAVES™
STATIM autoclaves
ce
a higher standard
StatimHelix
Now you can also obtain daily validation of STATIM’s sterilization cycle with a specifically designed
Process Challenge Device – StatimHelix that makes STATIM an S-Class autoclave that can prove
its effectiveness by both biological and mechanical means.
And with daily validation, you can be certain that STATIM is meeting the challenge of ensuring that yourself,
your staff and your patients are protected against cross-infection from contaminated instruments.
1. Unwrapped cycle
2. Wrapped cycle
3. Delicate cycle
4. Heavy duty cycle
5. Drying cycle
Cycles
Cycles
UNWRAPPED
WRAPPED
DELICATE
HEAVY DUTY ( unwrapped )
DRYING
Dri-Tec Drying Technology
Temp.
135° C.
135° C.
121° C.
135° C.
2000S
14 minutes
6 minutes
18.5 minutes
Air-dry only
10 minutes
( Dri-TecC )
5000S
17.5 minutes
9 minutes
23 minutes
11.5 minutes
15 minutes
( Dri-TecR )







- unwrapped instruments between patients for immediate use
- wrapped instruments that need to be stored in bags
- delicate items ( rubber / plastic )
- large loads ( unwrapped )
- drying wrapped bags or instruments left inside the cassette
The STATIM5000S has 5 Cycles
Class-S cycle
Technology
StatimHelix
Accurate
specifications
accessories
DRI-TEC DRYING TECHNOLOGY
The STATIM2000, 5000 ( and 7000 ) Cassette Autoclaves have each been designed to provide you
with a complete solution of Rapid sterilization balanced by Rapid drying.



STATIM2000S using DrI-TecC convection heat drying technology,
drying wrapped instrument loads in as little as 10 minutes.
STATIM5000S using
DrI-TecR radiant heat drying technology,
drying a full load in as little as 15 minutes
Rapid balanced drying is provided by STATIMs DRI-TEC DRYING TECHNOLOGY
Drying Technology
STATIM2000S and STATIM5000S S-Cycle autoclaves