The Aspheric IOLs may be injected through a 2.2mm to 2.8-3.0mm incision, micro-incision iols 1.6mm to 2.2mm,
or folded and inserted depending on the surgeon’s preference.
♦ INJECx™ - IOL Injector system - Injector, Cartridge and silicone Soft Tip.
♦ AFSx™ - Advanced Folding System
UV Absorbing Hydrophilic Acrylic 25% Equiconvex 0º 118.4 / 118.8 - HP57PA / HP70SA 5.3 / **Variable 1.46 25% -10.0D to +40.0D in 1.0 increments / +10.0D to +30.0D in 0.5 increments *+0.0D to +40.0D / +10.0D to +30.0D ***+10.0D to +30.0D in 0.5 increments
|
UPDATE - ASPHERICx™ SERIES FOLDABLE INTRAOCULAR LENSES
ASPHERICx™ positions more of the
available light on the fovea allowing the
patient to see objects more distinctly.
Products Foldable intraocular lens PMMA iols Viscoelastics Phacoemulsification system Intra-stromal inlays CTRs Sutures Instruments Sterilizers Economy Links Search
Aberration controlled, for a better vision
|
ASPHERICx™ Series
UPDATE Aberration controlled hydrophilic acrylic IOLs
Eye4Vision Ophthalmics is proud to offer exclusively designed small and micro-incision aspheric
hydrophilic acrylic foldable intraocular lenses made from the world's most stable UV Absorbing,
hydrophilic acrylic advanced polymer material.
AS OF 1 FEBRUARY 2011, ALL FOLDABLE LENSES OUT OF THE EYE4VISION
PORTFOLIO OF HYDROPHILIC ACRYLIC IOLS, INCLUDING THE COMPLETE LINE
OF MICRO-INCISION IOLS, CAN BE SUPPLIED IN SPHERIC, ASPHERIC,
OR 'HIGH CONTRAST'- YELLOW TINTED CONFIGURATION.
The aberration controlled aspheric foldable intraocular lens is developed using advanced optical
physics to supply the vision requirements of the patient.
The natural lens compensates for the positive aberration of the cornea.
The normal IOL is very forgiving but a little more dimmed
than the aberration controlled IOL
MODEL
Optic ( mm )
Diameter ( mm )
Design
Incision size ( mm )
Material
Optic style
Angulation
'A'-Constant
'AC'-Depth
Refractive index
Water content
Diopter range
Hydrophilic Acrylic
♦ 360º Square Edge
Download PDF 230Kb
♦
♦
♦
♦
♦
♦
♦
♦
♦
♦
♦
♦
♦
Numerous studies indicate that by reducing the amount of aberrations in the light waves going
through the eye, more rays are focused on the retina. This is translated into better distant vision
and better low light vision, as is illustrated in the photos below.
HP55CA 5.5 12.5 MOD. 'C' 2.2 - 2.8
|
Specifications:
ANNOUNCEMENT
IOL Implantation
Studies
FOLDABLES Multi-Focal Aspheric Hydroptic Softvault Diabetes FX8 Sulcus FX8 Sclera OPTIC Rx™ Hydrophobic
|
►
HP60CA 6.0 12.5 MOD. 'C' 2.2 - 2.8
|
HP60ZA 6.0 12.0 MOD. 'Z' 2.2 - 2.8 *
|
HP57PA 5.75 10.5 PLATE 2.2 - 2.8 *
|
HP60PA 6.0 11.0 PLATE 2.2 - 2.8 *
|
HP70PA 7.0 11.0 PLATE 2.2 - 2.8
|
HP70SA 7.0 11.0 / 13.0 PLATE 2.2 - 2.8 **
|
Get Adobe reader
Aberration controlled for a better vision
|
UV Absorbing Hydrophilic Acrylic 26% Equiconvex 0º 118.4 / 118.8 - HD57PA / HD70SA 5.3 / ** Variable - Sulcus / Sclera 1.46 26% +0.0D to +40.0D in 1.0D increments +10.0D to +30.0D in 0.5 increments
|
Eye4Vision Int'l.
®
HD55CA 5.5 12.5 MOD. 'C' 2.2 - 2.8
|
MODEL
Optic ( mm )
Diameter ( mm )
Design
Incision size ( mm )
Material
Optic style
Angulation
'A'-Constant
'AC'-Depth
Refractive index
Water content
Diopter range
HD60CA 6.0 12.5 MOD.'C' 2.2 - 2.8
|
HD60ZA 6.0 12.0 MOD. Z' 2.2 - 2.8
|
HD57PA 5.75 10.5 PLATE 2.2 - 2.8
|
♦
♦
♦
♦
♦
♦
♦
♦
♦
♦
♦
♦
♦
'HD' - HIGH CONTRAST
HD60PA 6.0 11.0 PLATE 2.2 - 2.8
|
HD70PA 7.0 11.0 PLATE 2.2 - 2.8
|
HD70SA 7.0 11.0 / 13.0 PLATE 2.2 - 2.8 **
|
Hydrophilic Acrylic
♦ 360º Square Edge
Specifications:
HM60PA 6.0 11.0 PLATE 1.6 - 2.2 Micro incision
|
New info:
▼