The Aspheric IOLs may be injected through a 2.2mm to 2.8-3.0mm incision, micro-incision iols 1.6mm to 2.2mm,
or folded and inserted depending on the surgeon’s preference.
INJECx™ - IOL Injector system - Injector, Cartridge and silicone Soft Tip.
AFSx™     - Advanced Folding System
UV Absorbing Hydrophilic Acrylic 25%
Equiconvex

118.4 / 118.8 - HP57PA / HP70SA
5.3 / **Variable
1.46
25%
-10.0D to +40.0D in 1.0 increments / +10.0D to +30.0D in 0.5 increments
*+0.0D to +40.0D / +10.0D to +30.0D  ***+10.0D to +30.0D in 0.5 increments
1
1
1
1
UPDATE - ASPHERICx™ SERIES FOLDABLE INTRAOCULAR LENSES
ASPHERICx™ positions more of the
available light on the fovea allowing the
patient to see objects more distinctly.
Products  Foldable intraocular lens  PMMA iols  Viscoelastics  Phacoemulsification system  Intra-stromal inlays  CTRs  Sutures  Instruments  Sterilizers  Economy  Links  Search
Update
ovd
ICR
foldables
CTR
pmma
products
phaco system
instruments
sterilizers
links
search
sutures
economy
Aberration controlled, for a better vision
ASPHERICx™ Series
UPDATE Aberration controlled hydrophilic acrylic IOLs
Eye4Vision Ophthalmics is proud to offer exclusively designed small and micro-incision aspheric
hydrophilic acrylic foldable intraocular lenses made from the world's most stable UV Absorbing,
hydrophilic acrylic
advanced polymer material.
AS OF 1 FEBRUARY 2011, ALL FOLDABLE LENSES OUT OF THE EYE4VISION
PORTFOLIO OF HYDROPHILIC ACRYLIC IOLS, INCLUDING THE COMPLETE LINE
OF MICRO-INCISION IOLS, CAN BE SUPPLIED IN SPHERIC, ASPHERIC,
OR 'HIGH CONTRAST'- YELLOW TINTED CONFIGURATION.
1
2
3
The aberration controlled aspheric foldable intraocular lens is developed using advanced optical
physics to supply the vision requirements of the patient.
ASPHERICx™
Standard IOL
20 Years of Age
The natural lens compensates for the positive aberration of the cornea.
The normal IOL is very forgiving but a little more dimmed
than the aberration controlled IOL
MODEL
Optic ( mm )
Diameter ( mm )
Design
Incision size ( mm )

Material
Optic style
Angulation
'A'-Constant
'AC'-Depth
Refractive index
Water content
Diopter range
Hydrophilic Acrylic
♦ 360º Square Edge
Download PDF 230Kb














Numerous studies indicate that by reducing the amount of aberrations in the light waves going
through the eye, more rays are focused on the retina. This is translated into better distant vision
and better low light vision, as is illustrated in the photos below.
HP55CA
5.5
12.5
MOD. 'C'
2.2 - 2.8
Specifications:
ANNOUNCEMENT
IOL Implantation
Studies
reader
pdf
FOLDABLES
Multi-Focal
Aspheric
Hydroptic
Softvault
Diabetes
FX8 Sulcus
FX8 Sclera
OPTIC Rx™
Hydrophobic

hydroptic
plate
hydrophobic
sulcus - sclera
diabetes
accommodating
multi-focal
HP60CA
6.0
12.5
MOD. 'C'
2.2 - 2.8
HP60ZA
6.0
12.0
MOD. 'Z'
2.2 - 2.8
*
HP57PA
5.75
10.5
PLATE
2.2 - 2.8
*
HP60PA
6.0
11.0
PLATE
2.2 - 2.8
*
HP70PA
7.0
11.0
PLATE
2.2 - 2.8
HP70SA
7.0
11.0 / 13.0
PLATE
2.2 - 2.8
**
Get Adobe reader
Aberration controlled
for a better vision
made in usa
UV Absorbing Hydrophilic Acrylic 26%
Equiconvex

118.4 / 118.8 - HD57PA / HD70SA
5.3 / ** Variable - Sulcus / Sclera
1.46
26%
+0.0D to +40.0D in 1.0D increments
+10.0D to +30.0D in 0.5 increments
TOP

Eye4Vision Int'l.
®
email
Home
index
HD55CA
5.5
12.5
MOD. 'C'
2.2 - 2.8
MODEL
Optic ( mm )
Diameter ( mm )
Design
Incision size ( mm )

Material
Optic style
Angulation
'A'-Constant
'AC'-Depth
Refractive index
Water content
Diopter range
HD60CA
6.0
12.5
MOD.'C'
2.2 - 2.8
HD60ZA
6.0
12.0
MOD. Z'
2.2 - 2.8
HD57PA
5.75
10.5
PLATE
2.2 - 2.8














Contact  Ophthalmic microscopes  Cataract Surgery Packs  VISION2020  Projects  Cold phaco  Donate here  Cataract kit  Sitemap
'HD' - HIGH CONTRAST
1
HD60PA
6.0
11.0
PLATE
2.2 - 2.8
HD70PA
7.0
11.0
PLATE
2.2 - 2.8
HD70SA
7.0
11.0 / 13.0
PLATE
2.2 - 2.8
**
Hydrophilic Acrylic
♦ 360º Square Edge
Specifications:
HM60PA
6.0
11.0
PLATE
1.6 - 2.2
Micro
incision
aspheric